  Datasheet File OCR Text:
 TOTAL POWER INT'L
PPS40-1/2/3
TPS40-1/2/3 40 WATT OPEN-FRAME SWITCHING POWER SUPPLY
SWITCHING MODE 40W OPEN FRAME POWER SUPPLIES
KEY FEATURES
*Universal input * Built-in EMI filter *Optional12VDC/24VDC/48VDC input
APPLICATIONS
*Telecommunications *Computer peripherals/ Lan & Hub *Test & industrial equipments *Medical instruments *Business machines
ELECTRICAL SPECIFICATIONS
*Input range-----------90~264 VAC, universal *Frequency------------47~63Hz *Inrush current--------25A typical, Cold start @25,115VAC *Efficiency------------65% ~80% typical at full load *EMI filter------------ FCC Class B conducted, CISPR 22 Class B conducted, EN55022 class B Conducted *Line regulation----- +/- 0.5% typical
EMI & EMC
*FCC part 15, Class B *CISPR 22 / EN55022, Class B *VCCI ,Class 2 *CE, EN 61000-3-2 (Class A) and -3; EN 61000-4-2,
INPUT
-3,-4.-5,-6 and -11 SAFETY APPROVAL
OUTPUT
*Maximum power----40W with 15 CFM forced air (Refer next page) *Hold-up time --------10ms typical at full load and 115 VAC nominal line *Overload protection-Short circuit protection *Overvoltage protection ------------Main output 20% to 40% above nominal output *Ripple/Noise -------- +/- 1% Max. @full load (Optional +/-0.5% per inquiry)
*UL1950 / c UL *Optional CSA 22.2, LEVEL 3 (COMPLY WITH) *TUV EN60950 *Optional UL 2601 (EMI Class A)(COMPLY WITH)
ENVIRONMENTAL
*Operating temperature : 0 to 50ambient; derate each output at 2.5% per degree from 50to 70 *Humidity: Operating; non-condensing, 5% to 95% *Vibration : 10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis *Storage temperature: -40 to 85 *Temperature coefficient: +/- 0.05% per degree C *MTBF demonstrated: >100,000 hours at full load and 25ambient conditions
Power Derating Curve
40W
15 CFM Forced Air Cooling
Output Power 20W (Watts) 10W
0W
0 10
30W
Natural Convection Cooling
20 30 40 50 60 70
20W 15W
Ambient Temperature( C)
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: sales@total-power.com http://www.total-power.com -1-
PPS40-1/2/3
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT
SWITCHING MODE 40W OPEN FRAME POWER SUPPLIES
PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE & NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1)
SI NGLE OUTPUT MODEL SELECTION CHART
TPS40-10 TPS40-11 TPS40-12 TPS40-13 TPS40-14 TPS40-15 TPS40-16
+5V +12V +15V +24V +48V +3.3V +28V
10% Typical 10% Typical 10% Typical 10% Typical 10% Typical 10% Typical 10% Typical
8A 3.3A 2.6A 1.6A 0.8A 9.6A 1.4A
10A 4.1A 3.2A 2A 1A 12A 1.8A
0A 0A 0A 0A 0A 0.96A 0A
3% 3% 3% 3% 3% 5% 3%
1% 1% 1% 1% 1% 1.5% 1%
50W Typical 50W Typical 50W Typical 50W Typical 50W Typical 50W Typical 50W Typical
DUAL OUTPUT MODEL SELECTION CHART
TPS40-20
+5 V +12V +5 V +48V +5 V - 5V +12V - 12V +15V - 15V +3.3V +5V
10% Typical Fixed 10% Typical Fixed 10% Typical Fixed 10% Typical Fixed 10% Typical Fixed 10% Typical Fixed
6A 1A 6A 0.25A 6A 2A 1.6A 1.6A 1.3A 1.3A 10A 1.5A
9.6A 1.6A 9.6A 0.4A 9.6A 3.2A 2.5A 2.5A 2A 2A 16A 2.4A
0.6A 0.1A 0.6A 0.03A 0.6A 0.2A 0.16A 0.16A 0.13A 0.13A 1A 0.15A
5% 5% 5% 5% 5% 10% 5% 10% 5% 10% 5% 5%
1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1.5% 1%
50W Typical 50W Typical 50W Typical 50W Typical 50W Typical 50W Typical
TPS40-21
TPS40-22
TPS40-23
TPS40-24
TPS40-25
TRIPLE OUTPUT MODEL SELECTION CHART
+ 5V
TPS40-30
10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed Fixed 10% Typical Fixed
5A 0.75A 1.2A 5A 0.75A 0.5A 5A 0.5A 0.5A 4A 1A 1A 4A 0.8A 0.7A 4A 0.5A 0.7A 4A 0.75A 1A 4A 0.75A 0.5A 2.4A 1.2A
8A 1.2A 1.9A 8A 1.2A 0.8A 8A 0.8A 0.8A 6.4A 1.6A 1.6A 6.4A 1.2A 1.1A 6.4A 0.8A 1.1A 6.4A 1.2A 1.6A 6.4A 1.2A 0.8A 3.8A 1.9A
0.5A 0.08A 0.12A 0.5A 0.08A 0.05A 0.5A 0.05A 0.05A 0.4A 0.1A 0.1A 0.4A 0.08A 0.07A 0.4A 0.05A 0.07A 0.4A 0.08A 0.1A 0.4A 0.08A 0.05A 0.24A 0.12A
5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5% 10% 5% 5%
1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 50W Typical 50W Typical 50W Typical 50W Typical 50W Typical 50W Typical 50W Typical 50W Typical 50W Typical
+12V -5V + 5V
TPS40-31
+12V -12V + 5V
TPS40-32
+15V -15V +5V
TPS40-33
+15V -5V +5V
TPS40-34
+15V -12V + 5V
TPS40-35
+24V -12V + 5V
TPS40-36
+12V -12V +5V
TPS40-37
+12V +24V +5V
TPS40-38
+12V
Fixed 10% 1% +48V 0.3A 0.5A 0.03A NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, input not less nominal line,0.1F and 47F Cap. on outputs. 3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed. 4) Detailed engineering specification of each model is available for inquiry. 5) Special output voltage/current inquiry is welcomed. 6) Specifications subject to change without notice. 7) 25% derated if 24 VDC input version;50% derated if 12 VDC input version;25% derated if additional cover.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: sales@total-power.com http://www.total-power.com -2-


▲Up To Search▲   

 
Price & Availability of TPS40-38

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X